Shandong Haiying Wuzhou Instrument Co., Ltd.

Shandong Haiying Wuzhou Instrument Co., Ltd.

Manufacturer from China
Active Member
5 Years
Home / Products / BSC Biosafety Cabinet /

Food Unit BSC Biosafety Cabinet Chemical Laboratories

Contact Now
Shandong Haiying Wuzhou Instrument Co., Ltd.
Country/Region:china
Contact Person:yisean
Contact Now

Food Unit BSC Biosafety Cabinet Chemical Laboratories

Ask Latest Price
Brand Name :HAIYING-Biosafety cabinet
Model Number :BHC-1000A2
Certification :CE ISO
Place of Origin :china
MOQ :1
Price :negotiable
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram
Packaging Details :The wooden case
Type :BSC Biosafety Cabinet
Overall size :1200×750×1950mm
Fluorescent lamp/UV lamp :21W×②/14W×①
Filter size :995×545×50mm
Wind direction :Top φ200mm
Air tightness :99.99≤E≤99.999
Average number of colonies :≤0.5(A/dish/hour)
Vibration/half peak amplitude :≤3μm(X·Y·Z)
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Food Unit Half Row Super Clean For Chemical Laboratories BSC Biosafety Cabinet

BSC Biosafety Cabinet Features:

◆ The safety cabinet is the primary laboratory isolation device that prevents the spread of harmful aerosols, protects experimenters, subjects and the environment, and is used safely in operations against highly hazardous microorganisms, toxic substances and radioactive oligonucleotides.

◆ Equipped with a special waterproof socket for operators to provide great convenience.

◆ Exceptional durability, reduced maintenance frequency

◆ Special filters are installed at the exhaust to control emission pollution.

◆ Equipped with a dedicated waterproof socket to provide great convenience for the operator.

◆ Using LED LCD panel control.

Weight 160kg
Power 0.8KW
Noise ≤65dB(A
Vibration/half peak amplitude ≤3μm(X·Y·Z)

Use of BSC Biosafety Cabinet:

1. Turn on the power.

2. Wear clean laboratory overalls, clean your hands, and wipe the working platform in the safety cabinet with 70% alcohol or other disinfectants.

3. Place the experimental objects in the safety cabinet as required.

4. Close the glass door, turn on the power switch, and if necessary, turn on the UV lamp to disinfect the surface of the experimental objects.

5. After the disinfection is completed, set to the working state of the safety cabinet, open the glass door to make the machine operate normally.

6. The equipment can be used after completing the self-cleaning process and running stably.

7. After finishing the work and removing the waste, wipe the working platform in the cabinet with 70% alcohol. Maintain the air circulation for a period of time to discharge pollutants in the work area.

8. Close the glass door, turn off the fluorescent lamp, and turn on the ultraviolet lamp to disinfect the cabinet.

9. After disinfection, turn off the power.

Maintenance of BSC Biosafety Cabinet:

In order to ensure the safety of the biological safety cabinet, the safety cabinet should be maintained and maintained regularly:

1. The work area of the safety cabinet should be cleaned and disinfected before and after each use.

2. After the service life of the HEPA filter expires, it should be replaced by a professional who has received special training in biological safety cabinets.

3. The laboratory biosafety manual promulgated by WHO, the U.S. biosafety cabinet standard NSF49 and the China Food and Drug Administration biosafety cabinet standard YY0569 all require one of the following conditions, the biosafety cabinet should be tested for safety: the installation is completed and put into use Before; annual routine inspection; when the safety cabinet is shifted; after replacing the HEPA filter and repairing internal components.

Food Unit BSC Biosafety Cabinet Chemical Laboratories

Inquiry Cart 0